2.7 Indicator Power Supply
1. Before connecting the indicator to the power
line, make sure that the line voltage corresponds
to the description on the identification label.
2. Use copper conductors only.
3. The power supply input is not fuse protected.
This should be provided externally.
4. For 24V the polarity is not important.
High voltage supply: 100 to 240Vac, -15%,
+10%, 50/60 Hz
Low voltage supply: 24Vac/dc, -15%, +10%
Recommended external fuse ratings are as
follows:-
For 24 V ac/dc, fuse type: T rated 2A 250V
For 100-240Vac, fuse type: T rated 2A 250V.
2.8 Example Wiring Diagram
This shows 32h8i connected to a strain gauge bridge.
N
L
Safety requirements for permanently connected
equipment state:
A switch or circuit breaker shall be included in
the building installation
It shall be in close proximity to the equipment
and within easy reach of the operator
It shall be marked as the disconnecting device for
the equipment.
Note: a single switch or circuit breaker can drive more
than one instrument.
Line
Neutral
Power Supply
L
N
Signal | Txdcr Supply
Fuse
- + Cal1 Cal2 Ext- Ext+ HF HE HD AC AB AA
N L 3D 3C 3B 3A LC LB 2B 2A 1B 1A
+
-
-
+
32h8i/SG Indicato
r
R
CAL
Strain
Gauge
24V
24V
24
24
16